changing temperature thresholds on EX switch

$
0
0

Since we wanted to receive alarms from Junos Space / Network Director about tempretures on EX switches , its possible . But if you want to receive temp. alarms once switch reaches specific temp. , then it need to be confgured on the EX .

 

Note: Change of Temperature thresholds on EX switch is not recommended by JTAC.

 

Tested by me on EX switch 3300 , JunOS: 12.3R9

 

This is hidden command , so type "set chassis temperature-threshold ?" at once

 

{master:0}[edit]
master@SW-EX3300# set chassis temp
^
syntax error.
master@SW-EX3300# set chassis temperature-threshold ?
Possible completions:
+ apply-groups Groups from which to inherit configuration data
+ apply-groups-except Don't inherit configuration data from these groups
fire-shutdown Threshold at which router will be shutdown within 10 seconds (degrees C)
red-alarm Threshold at which red alarm is set (degrees C)
red-alarm-if-failed-fan Threshold at which red alarm is set when bad fan present (degrees C)
yellow-alarm Threshold at which yellow alarm is set (degrees C)
yellow-alarm-if-failed-fan Threshold at which yellow alarm is set when bad fan present (degrees C)
{master:0}[edit]
master@SW-EX3300# set chassis temperature-threshold red-alarm ?
Possible completions:
<red-alarm> Threshold at which red alarm is set (degrees C)
{master:0}[edit]