Quantcast
Channel: All Ethernet Switching posts
Viewing all articles
Browse latest Browse all 10307

Re: Virtual Chassis LACP flap (GRES / NSB ?)

$
0
0

show log chassisd output:

 

Apr 27 17:00:32  adding message to chasssis manager queue, entries = 7
Apr 27 17:00:32  send: clear all Fan 7 alarms
Apr 27 17:00:32  adding message to chasssis manager queue, entries = 8
Apr 27 17:00:32  send: clear all Fan 8 alarms
Apr 27 17:00:32  adding message to chasssis manager queue, entries = 9
Apr 27 17:00:32  send: clear all Fan 9 alarms
Apr 27 17:00:32  adding message to chasssis manager queue, entries = 10
Apr 27 17:00:32  Fru type 5 in ch_do_fru_inits
Apr 27 17:00:32  initial startup complete
Jun  7 01:43:26  op 2 for ifd ge-0/0/14 
Jun  7 01:43:26  op 2 for ifd ge-0/0/15
Jun  7 01:43:26  op 2 for ifd ge-0/0/15
Jun  7 01:43:26  op 2 for ifd ge-4/0/12
Jun  7 01:43:26  op 2 for ifd ge-4/0/12
Jun  7 01:43:27  op 2 for ifd ge-1/0/12
Jun  7 01:43:27  op 2 for ifd ge-1/0/12
Jun  7 01:43:27  op 2 for ifd ge-2/0/24
Jun  7 01:43:27  op 2 for ifd ge-2/0/24
Jun  7 01:43:28  op 2 for ifd ge-3/0/24
Jun  7 01:43:28  op 2 for ifd ge-3/0/24
Jun  7 01:43:28  op 2 for ifd ge-3/0/25
Jun  7 01:43:28  op 2 for ifd ge-3/0/25
Jun  7 01:43:29  op 2 for ifd ge-1/0/5
Jun  7 01:43:29  op 2 for ifd ge-1/0/5
Jun  7 01:43:30  op 2 for ifd ge-2/0/25
Jun  7 01:43:30  op 2 for ifd ge-2/0/25
Jun  7 01:43:30  op 2 for ifd ge-4/0/5
Jun  7 01:43:30  op 2 for ifd ge-4/0/5
Jun  7 01:43:30  op 2 for ifd ge-0/0/46
Jun  7 01:43:30  op 2 for ifd ge-0/0/46
Jun  7 01:43:30  op 2 for ifd ge-1/0/46
Jun  7 01:43:31  op 2 for ifd ge-2/0/3
Jun  7 01:43:31  op 2 for ifd ge-2/0/3
Jun  7 01:43:31  op 2 for ifd ge-3/0/3
Jun  7 01:43:31  op 2 for ifd ge-3/0/3
Jun  7 01:43:33  op 2 for ifd ge-0/0/28
Jun  7 01:43:33  op 2 for ifd ge-0/0/35
Jun  7 01:43:33  op 2 for ifd ge-0/0/35
Jun  7 01:43:33  op 2 for ifd ge-0/0/36
Jun  7 01:43:33  op 2 for ifd ge-0/0/36
Jun  7 01:43:33  op 2 for ifd ge-1/0/6
Jun  7 01:43:33  op 2 for ifd ge-1/0/6
Jun  7 01:43:34  op 2 for ifd ge-4/0/6
Jun  7 01:43:34  op 2 for ifd ge-4/0/6
Jun  7 01:43:34  op 2 for ifd ge-4/0/18
Jun  7 01:43:34  op 2 for ifd ge-4/0/18
Jun  7 01:43:34  op 2 for ifd ge-1/0/18
Jun  7 01:43:34  op 2 for ifd ge-1/0/18
Jun  7 01:43:34  op 2 for ifd ge-1/0/19
Jun  7 01:43:34  op 2 for ifd ge-1/0/19
Jun  7 01:43:35  op 2 for ifd ge-4/0/19
Jun  7 01:43:35  op 2 for ifd ge-5/0/29
Jun  7 01:43:36  op 2 for ifd ge-5/0/29
Jun  7 01:43:36  op 2 for ifd ge-0/0/29
Jun  7 01:43:36  op 2 for ifd ge-0/0/29
Jun  7 01:46:58  op 2 for ifd ge-5/0/10
Jun  7 01:46:59  op 2 for ifd ge-0/0/10
Jun  7 01:46:59  op 2 for ifd ge-0/0/11
Jun  7 01:47:00  op 2 for ifd ge-5/0/11
Jun  7 01:47:03  op 2 for ifd ge-2/0/4
Jun  7 01:47:04  op 2 for ifd ge-3/0/4
Jun  7 01:47:05  op 2 for ifd ge-3/0/3
Jun  7 01:47:06  op 2 for ifd ge-3/0/3
Jun  7 01:47:08  op 2 for ifd ge-2/0/3
Jun  7 01:47:23  op 2 for ifd ge-5/0/17
Jun  7 01:47:24  op 2 for ifd ge-0/0/17
Jun  7 01:47:24  op 2 for ifd ge-5/0/16
Jun  7 01:47:25  op 2 for ifd ge-0/0/16
Jun  7 01:47:31  op 2 for ifd ge-5/0/15
Jun  7 01:47:32  op 2 for ifd ge-0/0/15
Jun  7 01:47:32  op 2 for ifd ge-0/0/14
Jun  7 01:47:33  op 2 for ifd ge-5/0/14

So any revelant info I think...

 

root@sw-cloud-ex3300-stack> show chassis routing-engine    
Routing Engine status:
  Slot 0:
    Current state                  Backup
    Temperature                 41 degrees C / 105 degrees F
    CPU temperature             41 degrees C / 105 degrees F
    DRAM                      1024
    Memory utilization          37 percent
    CPU utilization:
      User                       8 percent
      Background                 0 percent
      Kernel                     7 percent
      Interrupt                  0 percent
      Idle                      85 percent
    Model                          EX3300 48-Port
    Serial ID                      XXXXXXXXXXXXXX
    Start time                     2016-06-02 13:49:15 CEST
    Uptime                         5 days, 2 hours, 13 minutes, 16 seconds
    Last reboot reason             Router rebooted after a normal shutdown.
    Load averages:                 1 minute   5 minute  15 minute
                                       0.35       0.29       0.25
Routing Engine status:
  Slot 1:
    Current state                  Master
    Temperature                 41 degrees C / 105 degrees F
    CPU temperature             41 degrees C / 105 degrees F
    DRAM                      1024
    Memory utilization          42 percent
    CPU utilization:
      User                      54 percent
      Background                 0 percent
      Kernel                    45 percent
      Interrupt                  1 percent
      Idle                       0 percent
    Model                          EX3300 48-Port
    Serial ID                      XXXXXXXXXXXXXX
    Start time                     2016-06-02 12:46:09 CEST
    Uptime                         5 days, 3 hours, 17 minutes, 10 seconds
    Last reboot reason             Router rebooted after a normal shutdown.
    Load averages:                 1 minute   5 minute  15 minute
                                       2.33       1.89       1.80

{master:1}
root@sw-cloud-ex3300-stack> 
root@sw-cloud-ex3300-stack> show virtual-chassis           

Preprovisioned Virtual Chassis
Virtual Chassis ID: 002b.54b3.16f3
Virtual Chassis Mode: Enabled
                                           Mstr           Mixed Neighbor List
Member ID  Status   Serial No    Model     prio  Role      Mode ID  Interface
0 (FPC 0)  Prsnt    XXXXXXXXXXX ex3300-48t 129  Backup      NA  1  vcp-255/1/2
                                                                 5  vcp-255/1/3
1 (FPC 1)  Prsnt    XXXXXXXXXXX ex3300-48t 129  Master*     NA  0  vcp-255/1/2
                                                                 2  vcp-255/1/3
2 (FPC 2)  Prsnt    XXXXXXXXXXX ex3300-48t   0  Linecard    NA  1  vcp-255/1/2
                                                                 3  vcp-255/1/3
3 (FPC 3)  Prsnt    XXXXXXXXXXX ex3300-48t   0  Linecard    NA  4  vcp-255/1/2
                                                                 2  vcp-255/1/3
4 (FPC 4)  Prsnt    XXXXXXXXXXX ex3300-48t   0  Linecard    NA  3  vcp-255/1/2
                                                                 5  vcp-255/1/3
5 (FPC 5)  Prsnt    XXXXXXXXXXX ex3300-48t   0  Linecard    NA  4  vcp-255/1/2
                                                                 0  vcp-255/1/3

{master:1}
root@sw-cloud-ex3300-stack> 
root@sw-cloud-ex3300-stack> show virtual-chassis status 

Preprovisioned Virtual Chassis
Virtual Chassis ID: 002b.54b3.16f3
Virtual Chassis Mode: Enabled
                                           Mstr           Mixed Neighbor List
Member ID  Status   Serial No    Model     prio  Role      Mode ID  Interface
0 (FPC 0)  Prsnt    XXXXXXXXXXX ex3300-48t 129  Backup      NA  1  vcp-255/1/2
                                                                 5  vcp-255/1/3
1 (FPC 1)  Prsnt    XXXXXXXXXXX ex3300-48t 129  Master*     NA  0  vcp-255/1/2
                                                                 2  vcp-255/1/3
2 (FPC 2)  Prsnt    XXXXXXXXXXX ex3300-48t   0  Linecard    NA  1  vcp-255/1/2
                                                                 3  vcp-255/1/3
3 (FPC 3)  Prsnt    XXXXXXXXXXX ex3300-48t   0  Linecard    NA  4  vcp-255/1/2
                                                                 2  vcp-255/1/3
4 (FPC 4)  Prsnt    XXXXXXXXXXX ex3300-48t   0  Linecard    NA  3  vcp-255/1/2
                                                                 5  vcp-255/1/3
5 (FPC 5)  Prsnt    XXXXXXXXXXX ex3300-48t   0  Linecard    NA  4  vcp-255/1/2
                                                                 0  vcp-255/1/3

{master:1}
root@sw-cloud-ex3300-stack> 

I've never had any issue with release 12.3R9 during 1 year.

Recommended release, 12.3R12.4 can be the cause ...