Here is the diagnostic output for the Juniper6 port ge-0/0/30:
Physical interface: ge-0/0/30 Laser bias current : 6.320 mA Laser output power : 0.2850 mW / -5.45 dBm Module temperature : 29 degrees C / 83 degrees F Module voltage : 3.2980 V Receiver signal average optical power : 0.3273 mW / -4.85 dBm Laser bias current high alarm : Off Laser bias current low alarm : Off Laser bias current high warning : Off Laser bias current low warning : Off Laser output power high alarm : Off Laser output power low alarm : Off Laser output power high warning : Off Laser output power low warning : Off Module temperature high alarm : Off Module temperature low alarm : Off Module temperature high warning : Off Module temperature low warning : Off Module voltage high alarm : Off Module voltage low alarm : Off Module voltage high warning : Off Module voltage low warning : Off Laser rx power high alarm : Off Laser rx power low alarm : Off Laser rx power high warning : Off Laser rx power low warning : Off Laser bias current high alarm threshold : 12.000 mA Laser bias current low alarm threshold : 2.000 mA Laser bias current high warning threshold : 10.000 mA Laser bias current low warning threshold : 2.000 mA Laser output power high alarm threshold : 1.1000 mW / 0.41 dBm Laser output power low alarm threshold : 0.0600 mW / -12.22 dBm Laser output power high warning threshold : 1.0000 mW / 0.00 dBm Laser output power low warning threshold : 0.0850 mW / -10.71 dBm Module temperature high alarm threshold : 100 degrees C / 212 degrees F Module temperature low alarm threshold : -40 degrees C / -40 degrees F Module temperature high warning threshold : 85 degrees C / 185 degrees F Module temperature low warning threshold : -10 degrees C / 14 degrees F Module voltage high alarm threshold : 3.630 V Module voltage low alarm threshold : 2.970 V Module voltage high warning threshold : 3.465 V Module voltage low warning threshold : 3.134 V Laser rx power high alarm threshold : 1.8000 mW / 2.55 dBm Laser rx power low alarm threshold : 0.0000 mW / - Inf dBm Laser rx power high warning threshold : 1.0000 mW / 0.00 dBm Laser rx power low warning threshold : 0.0200 mW / -16.99 dBm
And here is what I can find for the other end (ASR1 Gig0/0/5):
The Transceiver in slot 0 subslot 0 port 5 is enabled. Module temperature = +23.464 C Transceiver Tx supply voltage = 3281.0 mVolts Transceiver Tx bias current = 5906 uAmps Transceiver Tx power = -4.9 dBm Transceiver Rx optical power = -5.5 dBm
IDPROM for transceiver GigabitEthernet0/0/5: Description = SFP or SFP+ optics (type 3) Transceiver Type: = GE SX (19) Product Identifier (PID) = GLC-SX-MMD Vendor Revision = A Serial Number (SN) = FNS18272505 Vendor Name = CISCO Vendor OUI (IEEE company ID) = 00.90.65 (36965) CLEI code = WOTRB9VBAA Cisco part number = 10-2626-01 Device State = Enabled. Date code (yy/mm/dd) = 14/07/03 Connector type = LC. Encoding = 8B10B NRZ Nominal bitrate = GE (1300 Mbits/s) Minimum bit rate as % of nominal bit rate = not specified Maximum bit rate as % of nominal bit rate = not specified The transceiver type is 19 Link reach for 9u fiber (km) = SX(550/270m) (0) 1xFC-MM(500/300m) (0) 2xFC-MM(300/150m) (0) ESCON-MM(2km) (0) Link reach for 9u fiber (m) = SX(550/270m) (0) 1xFC-MM(500/300m) (0) 2xFC-MM(300/150m) (0) ESCON-MM(2km) (0) Link reach for 50u fiber (m) = SX(550/270m) (55) LX(5km/550m) (55) LX(10km/550m) (55) Nominal laser wavelength = 850 nm. DWDM wavelength fraction = 850.0 nm. Supported options = Tx disable Loss of signal (standard implementation) Diagnostic monitoring = Digital diagnostics supported Diagnostics are internally calibrated Rx power measured is "Average power" Transceiver temperature operating range = -5 C to 85 C (extended) Minimum operating temperature = -5 C Maximum operating temperature = 85 C High temperature alarm threshold = +90.000 C High temperature warning threshold = +85.000 C Low temperature warning threshold = -5.000 C Low temperature alarm threshold = -10.000 C High voltage alarm threshold = 3600.0 mVolts High voltage warning threshold = 3500.0 mVolts Low voltage warning threshold = 3100.0 mVolts Low voltage alarm threshold = 3000.0 mVolts High laser bias current alarm threshold = 15.000 mAmps High laser bias current warning threshold = 12.000 mAmps Low laser bias current warning threshold = 2.000 mAmps Low laser bias current alarm threshold = 1.000 mAmps High transmit power alarm threshold = 0.0 dBm High transmit power warning threshold = -3.0 dBm Low transmit power warning threshold = -9.5 dBm Low transmit power alarm threshold = -13.5 dBm High receive power alarm threshold = 3.0 dBm High receive power warning threshold = 0.0 dBm Low receive power warning threshold = -17.0 dBm Low receive power alarm threshold = -21.0 dBm External Calibration: bias current slope = 1.000 External Calibration: bias current offset = 0