Re: Router-on-a stick Cisco Router with Juniper Switch

$
0
0

Here is the diagnostic output for the Juniper6 port ge-0/0/30:

 

Physical interface: ge-0/0/30
    Laser bias current                        :  6.320 mA
    Laser output power                        :  0.2850 mW / -5.45 dBm
    Module temperature                        :  29 degrees C / 83 degrees F
    Module voltage                            :  3.2980 V
    Receiver signal average optical power     :  0.3273 mW / -4.85 dBm
    Laser bias current high alarm             :  Off
    Laser bias current low alarm              :  Off
    Laser bias current high warning           :  Off
    Laser bias current low warning            :  Off
    Laser output power high alarm             :  Off
    Laser output power low alarm              :  Off
    Laser output power high warning           :  Off
    Laser output power low warning            :  Off
    Module temperature high alarm             :  Off
    Module temperature low alarm              :  Off
    Module temperature high warning           :  Off
    Module temperature low warning            :  Off
    Module voltage high alarm                 :  Off
    Module voltage low alarm                  :  Off
    Module voltage high warning               :  Off
    Module voltage low warning                :  Off
    Laser rx power high alarm                 :  Off
    Laser rx power low alarm                  :  Off
    Laser rx power high warning               :  Off
    Laser rx power low warning                :  Off
    Laser bias current high alarm threshold   :  12.000 mA
    Laser bias current low alarm threshold    :  2.000 mA
    Laser bias current high warning threshold :  10.000 mA
    Laser bias current low warning threshold  :  2.000 mA
    Laser output power high alarm threshold   :  1.1000 mW / 0.41 dBm
    Laser output power low alarm threshold    :  0.0600 mW / -12.22 dBm
    Laser output power high warning threshold :  1.0000 mW / 0.00 dBm
    Laser output power low warning threshold  :  0.0850 mW / -10.71 dBm
    Module temperature high alarm threshold   :  100 degrees C / 212 degrees F
    Module temperature low alarm threshold    :  -40 degrees C / -40 degrees F
    Module temperature high warning threshold :  85 degrees C / 185 degrees F
    Module temperature low warning threshold  :  -10 degrees C / 14 degrees F
    Module voltage high alarm threshold       :  3.630 V
    Module voltage low alarm threshold        :  2.970 V
    Module voltage high warning threshold     :  3.465 V
    Module voltage low warning threshold      :  3.134 V
    Laser rx power high alarm threshold       :  1.8000 mW / 2.55 dBm
    Laser rx power low alarm threshold        :  0.0000 mW / - Inf dBm
    Laser rx power high warning threshold     :  1.0000 mW / 0.00 dBm
    Laser rx power low warning threshold      :  0.0200 mW / -16.99 dBm

 

And here is what I can find for the other end (ASR1 Gig0/0/5):

 

The Transceiver in slot 0 subslot 0 port 5 is enabled.
  Module temperature                        = +23.464 C
  Transceiver Tx supply voltage             = 3281.0 mVolts
  Transceiver Tx bias current               = 5906 uAmps
  Transceiver Tx power                      = -4.9 dBm
  Transceiver Rx optical power              = -5.5 dBm
IDPROM for transceiver GigabitEthernet0/0/5:
  Description                               = SFP or SFP+ optics (type 3)
  Transceiver Type:                         = GE SX (19)
  Product Identifier (PID)                  = GLC-SX-MMD          
  Vendor Revision                           = A   
  Serial Number (SN)                        = FNS18272505     
  Vendor Name                               = CISCO           
  Vendor OUI (IEEE company ID)              = 00.90.65 (36965)
  CLEI code                                 = WOTRB9VBAA
  Cisco part number                         = 10-2626-01
  Device State                              = Enabled.
  Date code (yy/mm/dd)                      = 14/07/03
  Connector type                            = LC.
  Encoding                                  = 8B10B
                                              NRZ
  Nominal bitrate                           = GE (1300 Mbits/s)
  Minimum bit rate as % of nominal bit rate = not specified
  Maximum bit rate as % of nominal bit rate = not specified
  The transceiver type is 19 
  Link reach for 9u fiber (km)              = SX(550/270m) (0)
                                              1xFC-MM(500/300m) (0)
                                              2xFC-MM(300/150m) (0)
                                              ESCON-MM(2km) (0)
  Link reach for 9u fiber (m)               = SX(550/270m) (0)
                                              1xFC-MM(500/300m) (0)
                                              2xFC-MM(300/150m) (0)
                                              ESCON-MM(2km) (0)
  Link reach for 50u fiber (m)              = SX(550/270m) (55)
                                              LX(5km/550m) (55)
                                              LX(10km/550m) (55)
  Nominal laser wavelength                  = 850 nm.
  DWDM wavelength fraction                  = 850.0  nm.
  Supported options                         = Tx disable
                                              Loss of signal (standard implementation)
  Diagnostic monitoring                     = Digital diagnostics supported
                                              Diagnostics are internally calibrated
                                              Rx power measured is "Average power"
  Transceiver temperature operating range   = -5 C to 85 C (extended)
  Minimum operating temperature             = -5 C
  Maximum operating temperature             = 85 C
  High temperature alarm threshold          = +90.000 C
  High temperature warning threshold        = +85.000 C
  Low temperature warning threshold         =  -5.000 C
  Low temperature alarm threshold           =  -10.000 C
  High voltage alarm threshold              = 3600.0 mVolts
  High voltage warning threshold            = 3500.0 mVolts
  Low voltage warning threshold             = 3100.0 mVolts
  Low voltage alarm threshold               = 3000.0 mVolts
  High laser bias current alarm threshold   = 15.000 mAmps
  High laser bias current warning threshold = 12.000 mAmps
  Low laser bias current warning threshold  = 2.000 mAmps
  Low laser bias current alarm threshold    = 1.000 mAmps
  High transmit power alarm threshold       =  0.0 dBm
  High transmit power warning threshold     = -3.0 dBm
  Low transmit power warning threshold      = -9.5 dBm
  Low transmit power alarm threshold        = -13.5 dBm
  High receive power alarm threshold        =  3.0 dBm
  High receive power warning threshold      =  0.0 dBm
  Low receive power warning threshold       = -17.0 dBm
  Low receive power alarm threshold         = -21.0 dBm
  External Calibration: bias current slope  = 1.000
  External Calibration: bias current offset = 0

 

 

 