Hello Community,
Recently I set a Virtual chassis with a couple of EX4550. Everything worked as expected during the config. Until the testing came.
So I have each one of the EX4550 connected in their Mgmt port to a main Switch.
The VME has been set and it can be ping on either one of the ports. So far so good. However.
When I perform a Master switch from member 0 to 1 I lost about 8 pings
Both member statue's is Present in the virtual chassis config.
I checked this Learning byte
https://www.youtube.com/watch?v=7jSzgalUXeI&list=PLEXqnwPA6HuBVbfTKeYeJhjgLG9oi_FIE&t=186s&index=9
set the same config but I still keep getting packet lost.
Any Idea?
here is the VS config.
set system commit synchronize
set chassis redundancy graceful-switchover
set routing-options nonstop-routing
set virtual-chassis preprovisioned
set virtual-chassis member 0 role routing-engine
set virtual-chassis member 0 serial-number XXXXXXXXXX1
set virtual-chassis member 1 role routing-engine
set virtual-chassis member 1 serial-numberXXXXXXXXXX2
set virtual-chassis mac-persistence-timer disable
thanks