Quantcast
Channel: All Ethernet Switching posts
Viewing all articles
Browse latest Browse all 10307

Troubleshooting error message

$
0
0

I have two EX4300 switchs in a stack. When I first got them I had them lincked usinging optic calbles, they are now using the standard stackign cabels, and only xe-0/2/2-3 & 1/2/2-3 are configured. So I was suporsed to see the error below shoing a failed connnecion:

 

Apr 10 09:16:23 pfex: Link 51 FAILED
Apr 10 09:16:23 pfex: [EX-BCM PIC] ex_bcm_pic_optics_periodic: Failed to read eeprom of Optic 1 of Pic 2
Apr 10 09:16:23 fpc0 Link 51 FAILED
Apr 10 09:16:23 fpc0 [EX-BCM PIC] ex_bcm_pic_optics_periodic: Failed to read eeprom of Optic 1 of Pic 2
Apr 10 09:16:24 fpc1 Link 50 FAILED
Apr 10 09:16:24 fpc1 [EX-BCM PIC] ex_bcm_pic_optics_periodic: Failed to read eeprom of Optic 0 of Pic 2
Apr 10 09:16:24 fpc1 Link 51 FAILED
Apr 10 09:16:24 fpc1 [EX-BCM PIC] ex_bcm_pic_optics_periodic: Failed to read eeprom of Optic 1 of Pic 2
Apr 10 09:16:24 pfex: Link 50 FAILED
Apr 10 09:16:24 pfex: [EX-BCM PIC] ex_bcm_pic_optics_periodic: Failed to read eeprom of Optic 0 of Pic 2

The slots look fine

> show chassis pic fpc-slot 0 pic-slot 2
FPC slot 0, PIC slot 2 information:
  Type                             4x 1G/10G SFP/SFP+
  State                            Online
  PIC version                  3.2
  Uptime                         56 days, 20 hours, 24 minutes, 38 seconds

PIC port information:
                         Fiber                    Xcvr vendor       Wave-    Xcvr
  Port Cable type        type  Xcvr vendor        part number       length   Firmware
  3    10GBASE AOC 10M   n/a   JUNIPER-FINISAR    FCBG110SD1C10-J1  1024 nm  0.0

> show chassis pic fpc-slot 1 pic-slot 2
FPC slot 1, PIC slot 2 information:
  Type                             4x 1G/10G SFP/SFP+
  State                            Online
  PIC version                  3.2
  Uptime                         56 days, 20 hours, 24 minutes, 38 seconds

PIC port information:
                         Fiber                    Xcvr vendor       Wave-    Xcvr
  Port Cable type        type  Xcvr vendor        part number       length   Firmware
  3    10GBASE AOC 10M   n/a   JUNIPER-FINISAR    FCBG110SD1C10-J1  1024 nm  0.0

I also confirmed that the ports wer no longer used as vc-ports and were unconfigured. 

> show configuration interfaces xe-0/2/1 | display inheritance

{master:0}
> show configuration interfaces xe-1/2/0 | display inheritance

{master:0}

> show virtual-chassis vc-port
fpc0:
--------------------------------------------------------------------------
Interface   Type              Trunk  Status       Speed        Neighbor
or                             ID                 (mbps)       ID  Interface
PIC / Port
1/0         Configured          6    Up           40000        1   vcp-255/1/1
1/1         Configured          6    Up           40000        1   vcp-255/1/0
1/3         Configured               Absent
1/2         Configured               Absent

fpc1:
--------------------------------------------------------------------------
Interface   Type              Trunk  Status       Speed        Neighbor
or                             ID                 (mbps)       ID  Interface
PIC / Port
1/0         Configured          6    Up           40000        0   vcp-255/1/1
1/1         Configured          6    Up           40000        0   vcp-255/1/0
1/2         Configured               Absent
1/3         Configured               Absent

I am open to any additional guidance on where to look next for the source of these errors.