Quantcast
Channel: All Ethernet Switching posts
Viewing all articles
Browse latest Browse all 10307

Re: Ex4600 'Error in: SBUS transaction.'

$
0
0

HI Joel

 

Feb 23 09:57:38 swi-02 fpc1 LBCM-L2,pfe_bcm_l2_mac_add(),702:same mac entry
Feb 23 09:57:38 swi-02 fpc1 LBCM-L2,pfe_bcm_l2_mac_add(),690:modid 1 port 0 is_lag_port 1 flags 0x10cc0 trunk_id 1 port 0
Feb 23 09:57:38 swi-02 fpc1 LBCM-L2,pfe_bcm_l2_mac_add(),702:same mac entry
Feb 23 09:57:38 swi-02 fpc1 LBCM-L2,pfe_bcm_l2_mac_add(),690:modid 1 port 0 is_lag_port 1 flags 0x108c0 trunk_id 1 port 0
Feb 23 09:57:38 swi-02 fpc1 LBCM-L2,pfe_bcm_l2_mac_add(),702:same mac entry
Feb 23 09:57:38 swi-02 fpc1 LBCM-L2,pfe_bcm_l2_mac_add(),690:modid 1 port 0 is_lag_port 1 flags 0x108c0 trunk_id 1 port 0
Feb 23 09:57:38 swi-02 fpc1 LBCM-L2,pfe_bcm_l2_mac_add(),702:same mac entry
Feb 23 09:57:38 swi-02 fpc1 LBCM-L2,pfe_bcm_l2_mac_add(),690:modid 1 port 0 is_lag_port 1 flags 0x10cc0 trunk_id 1 port 0
Feb 23 09:57:38 swi-02 fpc1 LBCM-L2,pfe_bcm_l2_mac_add(),702:same mac entry
Feb 23 09:59:04 swi-02 fpc1 LBCM-L2,pfe_bcm_l2_mac_add(),690:modid 1 port 47984 is_lag_port 1 flags 0x104c0 trunk_id 1

On QFX5100 and EX4600 switches, every time a MAC address is learned, some messages might be output to syslog and be repeated frequently. The logged messages have no impact on service traffic.

https://prsearch.juniper.net/PR1171523

Feb 23 09:59:04 swi-02 fpc0 LBCM-L2,pfe_bcm_l2_mac_add(),702:same mac entry

Feb 23 09:59:09 swi-02 fpc1 Unit: 0
Feb 23 09:59:09 swi-02 fpc1 Mem:
Feb 23 09:59:09 swi-02 fpc1 Parity error..
Feb 23 09:59:09 swi-02 fpc1 Error in: SBUS transaction.
Feb 23 09:59:09 swi-02 fpc1 Blk: 1, Pipe: 1, Address: 0x28401698, base: 0x10, stage: 10, index: 5784
Feb 23 09:59:09 swi-02 fpc1 Unit 0: mem: 2046=L3_DEFIP blkoffset:10
Feb 23 09:59:09 swi-02 fpc1 Unit 0: RESTORE[from X pipe]: L3_DEFIP[2046] blk: ipipe0 index: 5784
Feb 23 09:59:09 swi-02 fpc1 Unit: 0
Feb 23 09:59:09 swi-02 fpc1 Mem:
Feb 23 09:59:09 swi-02 fpc1 Parity error..
Feb 23 09:59:09 swi-02 fpc1 Error in: SBUS transaction.
Feb 23 09:59:09 swi-02 fpc1 Blk: 1, Pipe: 1, Address: 0x284016a8, base: 0x10, stage: 10, index: 5800
Feb 23 09:59:09 swi-02 fpc1 Unit 0: mem: 2046=L3_DEFIP blkoffset:10
Feb 23 09:59:09 swi-02 fpc1 Unit 0: RESTORE[from X pipe]: L3_DEFIP[2046] blk: ipipe0 index: 5800

External-Title
QFX5100 reports false parity error messages like "soc_mem_array_sbusdma_read" & "soc_ser_correction: mem write".
Customer-Risk
minor
Release-Note
SDK can raise false alarms for parity error messages like  "soc_mem_array_sbusdma_read" & "soc_ser_correction: mem write" on QFX5100.


Workaround-Provided
yes
Workaround
Reboot resolves the issue temporarily. Issue might come back later.


External-Description
1. Software Development Kit mistakenly believes existence of parity errors.  This false reporting manifests itself via following log messages on the switch:

Feb 10 14:41:47.422 H01-387A-D25-250 feb1 _soc_mem_array_sbusdma_read: ING_FLEX_CTR_COUNTER_TABLE_5_X.ipipe0 failed(ERR)
Feb 10 14:41:47.422 H01-387A-D25-250 feb1 H/W received sbus nack with error bit set.
Feb 10 14:41:47.423 H01-387A-D25-250 feb1 Error in: SBUS transaction.
Feb 10 14:41:47.424 H01-387A-D25-250 feb1 Unit 0: soc_ser_correction: mem write ING_FLEX_CTR_OFFSET_TABLE_4.ipipe0[33797] failed: Invalid parameter
Nov 17 07:03:25   fpc0 Unit: 0  
Nov 17 07:03:25   fpc0 Mem:
Nov 17 07:03:25   fpc0 Parity error..
Nov 17 07:03:25   fpc0 Error in: SBUS transaction.
Nov 17 07:03:25   fpc0 Blk: 1, Pipe: 0, Address: 0x284013db, base: 0x10, stage: 10, index: 5083
Nov 17 07:03:25   fpc0 Unit 0: mem: 2046=L3_DEFIP blkoffset:10
Nov 17 07:03:25   fpc0 Unit 0: RESTORE[from Y pipe]: L3_DEFIP[2046] blk: ipipe0 index: 5083
 
2. The SW fix for this issue is in 14.1X53-D37 onwards

https://prsearch.juniper.net/PR1161821

 

Thanks

Partha

 

Hope the information helps.


Viewing all articles
Browse latest Browse all 10307

Trending Articles