I resolved the problem, I was setting the wrong port for the pic-slot.
Once I set to port 24 and 25, all came up.
root> show virtual-chassis vc-port fpc0: -------------------------------------------------------------------------- Interface Type Trunk Status Speed Neighbor or ID (mbps) ID Interface PIC / Port 0/24 Configured -1 Up 40000 3 vcp-255/0/24 0/25 Configured -1 Up 40000 2 vcp-255/1/0 fpc1: -------------------------------------------------------------------------- Interface Type Trunk Status Speed Neighbor or ID (mbps) ID Interface PIC / Port 1/0 Configured -1 Up 40000 2 vcp-255/1/1 1/1 Configured -1 Up 40000 3 vcp-255/0/25 fpc2: -------------------------------------------------------------------------- Interface Type Trunk Status Speed Neighbor or ID (mbps) ID Interface PIC / Port 1/0 Configured -1 Up 40000 0 vcp-255/0/25 1/1 Configured -1 Up 40000 1 vcp-255/1/0 fpc3: -------------------------------------------------------------------------- Interface Type Trunk Status Speed Neighbor or ID (mbps) ID Interface PIC / Port 0/24 Configured -1 Up 40000 0 vcp-255/0/24 0/25 Configured -1 Up 40000 1 vcp-255/1/1 {master:0}