Re: EX4200 Uplink module

$
0
0

"4. fpc 0 ports can not be converted to virtual chassis on ex 4200."

 

This is incorrect. Ports 0-23 can be configured as 1Gb copper vc ports.

 

test@test> show virtual-chassis vc-port local 
Interface   Type              Trunk  Status       Speed        Neighbor
or                             ID                 (mbps)       ID  Interface
PIC / Port
vcp-0       Dedicated           1    Up           32000        3   vcp-0  
vcp-1       Dedicated           2    Up           32000        0   vcp-1  
0/23        Configured         -1    Down         1000 

test@test> show chassis hardware    
Hardware inventory:
Item             Version  Part number  Serial number     Description
FPC 1            REV 19   750-021255   xxxxxxxxxxxx      EX4200-48P, 48 POE
  CPU                     BUILTIN      BUILTIN           FPC CPU
  PIC 0                   BUILTIN      BUILTIN           48x 10/100/1000 Base-T
  PIC 1          REV 04   711-026017   xxxxxxxxxxxxx      2x 10GE SFP+