Re: Ex4300 Virtual Chassis member issue

$
0
0
Hi,

Have you tried to enable the no-split-detection statement ?

{master:0}[edit]
root@switch# set virtual-chassis ?
Possible completions:
+ apply-groups Groups from which to inherit configuration data
+ apply-groups-except Don't inherit configuration data from these groups
> fast-failover Fast failover mechanism
id Virtual chassis identifier, of type ISO system-id
> mac-persistence-timer How long to retain MAC address when member leaves virtual chassis
> member Member of virtual chassis configuration
no-split-detection Disable split detection. This command is recommended to only be enabled in a 2 member setup
preprovisioned Only accept preprovisioned members
> traceoptions Global tracing options for virtual chassis

{master:0}[edit]
root@switch# set virtual-chassis no-split-detection
root@switch# commit

If not , and if this didn't help , can you share with us the following ?
1- related configuration
2- versions