Re: How to verify MAC-Move or Enable MAC-Move logs
Hi,You can enable different actions on mac-move : Configuring MAC Move Limiting (CLI Procedure) //RegardsAD
View ArticleRe: How to verify MAC-Move or Enable MAC-Move logs
Thanks for that , is there a way to send this info to Syslog ?Also the buffer seems to be pretty low , any way to increase the buffer size .using following show ethernet-switching mac-learning-log
View ArticleRe: How to verify MAC-Move or Enable MAC-Move logs
@adwivedi Good one ; i will check . thanks
View ArticleRe: How to verify MAC-Move or Enable MAC-Move logs
Hi Folks,Just my 2 cents on this… I love to analyze the logs on the box with inbuilt shell as below, start shell % cat macMar 18 21:33:14 2018 vlan_name TEST mac 00:05:86:74:e5:ef was learned on ae10.0...
View ArticleRe: Flapping VSTP on a single port
I have the same issue. EX4300, 14.1X53-D45.3.Does anybody have a solution ?
View Articlevlan switching with IRB - advice needed
Looking for recommended configuration for the following:Current config: 5 switches/virtual chassis. Using a single default vlan and all interfaces are configured as access, including links between...
View ArticleRe: vlan switching with IRB - advice needed
Yes, irb addresses on just one switch (or two, and use vrrp for failover). You can leave the existing irb.0 addresses in place for management.
View ArticleEX8208 Disable VC
Hi All-- I bought a used EX8208 to test some cos configurations and I'm having a hard time getting it out of VC mode, which I think may be preventing the line cards from coming up properly. It is...
View ArticleRe: EX8208 Disable VC
Okay, I downgraded to 9.6R3 -- no chance of virtual chassis there My linecards are now fully up. Will see what happens after upgrading back to 12 or 15. root> show chassis hardware Hardware...
View ArticleRe: EX8208 Disable VC
And after upgrading to 12.3 the behavior is back--linecard status. warning: This chassis is operating in a non-master role as part of a virtual-chassis (VC) system. warning: Use of interactive...
View ArticleRe: EX8208 Disable VC
And the answer is... root> set chassis virtual-chassis disable This will reboot the RE(s) Do you want to continue ? [yes,no] (no) yes
View ArticleRe: vlan switching with IRB - advice needed
As it is a VC, one irb will suffice your requirement.
View ArticleRe: vlan switching with IRB - advice needed
Hi! irb on any one switch should suffice the requirement for routing.
View ArticleSelective Q-In-Q on QFX5100
Hi, I have QFX5100 and need selective Q-In-Q.For example, on port xe-0/0/0 and need map:- CVLAN-s 100-200 = SVLAN 25- CVLAN-s 302, 303, etc. = SVLAN 45- etc...
View ArticleRe: How to verify MAC-Move or Enable MAC-Move logs
There is no configuration option to send the show command logs to syslog. You would have to create an event script on the box to run the command periodically and send the syslog messages for the mac...
View ArticleRe: Ex3300 Virtual Chassis preprovisioning issue.
I'm on 15.1R5.5. I did not try to shut down member 0, also I did not try request virtual-chassis reactivate. This was production and I was under the gun to get it up and running. I will try during a...
View ArticleRe: vlan switching with IRB - advice needed
Hi, You can also go through the below techpub and learning byte. Understanding Integrated Routing and Bridging Interfaces and Routed VLAN Interfaces on EX Series Switches Configuring IRB Interfaces on...
View ArticleSwitch Not Booting Correctly
I have an EX2300 switch that quit working after hours yesterday. It's hooked to a UPS so I don't believe any sort of restart happened. It looks as if it thinks it should be a part of a virtual chassis,...
View ArticleRe: Switch Not Booting Correctly
look like virtul chassis has splited due to switch reboot with different OS.. or other reasons. that we can find out only to verify the logs in routing engine member. Can you provide the logs from...
View Article