Re: 2 members Virtual chassis traffic handling
Hi Spuluka, Actually, I rebuild the EX2200VC by the steps as below:1. Split EX2200 Virtual Chassis into two standalone switches and power on them2. Factory default and zeroized the EX2200 Switches3....
View ArticleRe: 2 members Virtual chassis traffic handling
run this command#set system commit synchronize#commit full display the results of some >show virtual-chassis ?>show virtual-chassis status
View ArticleRe: 2 members Virtual chassis traffic handling
Standard stuff: do you see link light on both interfaces PC's are plugged into? Does show interface terse show those interfaces are up? Perform show ethernet-switching table and do you see the PC MAC...
View ArticleRe: 2 members Virtual chassis traffic handling
Hi rccpgm, Thanks for your reminding. I also tested two PCs connected to master switch then they can ping with each other until they connected to the different member switch, the connection is...
View ArticleRe: 2 members Virtual chassis traffic handling
Yes you are correct. Why are you not posting the resuls of the show commands requested to view the vc status, statistics, path, interface configurations, interface terse output, ethernet-switching...
View ArticleRe: 2 members Virtual chassis traffic handling
Agree but I expecting that maybe your 2nd switch could be bad or have some issue besides setup or config. Yes???Sent from my iPhone
View ArticleRe: 2 members Virtual chassis traffic handling
Hi all, Finally, I can ping with each other by add the command set interface ge-1/0/0~45 unit 0 family ethernet-switching. But is it normal behavior? I suppose all interfaces should be act as ethernet...
View ArticleRe: 2 members Virtual chassis traffic handling
You do not have to configure all interfaces for ethernet-switching in order for it work. If the interface in question is required then yes. You do not have to manually configure each interface...
View ArticleHeat output from EX switches
Does anyone know what the heat output is for the EX3400 & EX2200-C? I can not find this information anywhere.
View ArticleRe: Heat output from EX switches
I assume you are trying to measure an AC load. If so, you can use the equipment watts rating and convert to BTU load using the standard formulaBTU load=3.412141633xWatts...
View ArticleRe: Heat output from EX switches
Hi Regalis, usually your local Juniper Partner should be able to get hold of this information. There is a document provided to Juniper and Partner SE's with precise numbers for wiring closet switches...
View ArticleRe: 2 members Virtual chassis traffic handling
As lyndidon stated, you should not have to configure the interfaces as ethernet-switching, this should be default configuration. You did state previousy that you performed: Factory default and zeroized...
View ArticleQFX5100 MC-LAG with QinQ
I have a problem with my qfx5100. we have a downstream device that is connected into the mc-lag pair.this downstream device sends up 4 vlan tags. we want to add an S-TAG to these vlans and send out via...
View ArticleRe: Can ex3300 and ex4200 rebuild /var during a scheduled reboot after...
I don't suppose you figured anything out? I am struggling with precisely this issue. I can fix it with console but that is not always an option.
View ArticleRe: Can ex3300 and ex4200 rebuild /var during a scheduled reboot after...
Not figured out anything automatic: If you have file system damage, youreally do have to go visit the switch, connect via console, and boot intosingle user mode to manually run fsck -y until it comes...
View ArticleRe: DAC Breakout Cables for the EX4300 Switch
Is there any way to connect a server using SFP+ to a EX4300 QSFP port? We would only need one port, and don't have the module in the front. Does for example a SFP -> QSFP adapter work, or could we...
View ArticleRe: QFX5100 MC-LAG with QinQ
Where is the other side of your QinQ tunnel? This configuration seems to take the vlan list out of local layer 2 and into the QinQ service. So I expect them to no longer be in the local mac table and...
View ArticleRe: QFX5100 MC-LAG with QinQ
Below is a working config snippet for Q-in-Q config between EX9200 and EX4600. EX4600 and QFX5100 should work with exact same config. Since it looks like your QFX side is right, I'd check the MC-LAG...
View ArticleRe: Can ex3300 and ex4200 rebuild /var during a scheduled reboot after...
Thank you so much for taking the time to respond! We've been running nand-mediack a bunch but its been a weak predictor of which ones are going to fail so far. I found a suggestion elsewhere on J-net...
View ArticleRe: QFX5100 MC-LAG with QinQ
Hi, I dont have a problem in configuring the QinQ service, this works but in a standalone box. When we put this on an MC-LAG interface the MAC learning doesnt seem to be wrking correctly between both...
View Article