Virtual Chassis EX4550
Hi Guys, I have a Virtual Chassis with two Ex4550, the VC ports are configured on Electric Ports, I mean not on Optical ports, the Virtual Chassis is UP, Is necessary enable the failover on xe- ports,...
View ArticleRe: Difference between CON and MGMT port on back of EX-4200?
This is one of the most basic principles of all Junos products - seperation of Control Plane and Data Plane, so that one does NOT lose mgmt visability under such circumstance. Both CON and Mgmt are...
View ArticleCannot get native vlan to pass data traffic on ELS EX4300
Hi guys, I am new to Junos. Having trouble getting native vlan to work for WAPs. I also tested with a cisco 3560 with no luck. However config was working on old EX2200. I also used ELS translater...
View ArticleRe: SNMP check for queue data rate
You can also try searching the MIB explorer with the specific version of Junos on the EX switch to see what the supported cos parameters are. https://contentapps.juniper.net/mib-explorer/search.jsp
View ArticleRe: Cannot get native vlan to pass data traffic on ELS EX4300
Hello, Can you try try following command: delete interface ge-0/0/10 unit 0 family ethernet-switching vlan members 51 Note:- Without removing above command, EX is able to assign vlan 51 to all incoming...
View ArticleRe: Virtual Chassis EX4550
Hello, All supported SFP, SFP+ & XFP uplink connections (10gig ports only) between EX4550 can be configured as VCPs. However advantage of using dedicated VCPs on EX4550 is that you do not need...
View ArticleRe: Cannot get native vlan to pass data traffic on ELS EX4300
HI Rushi, Tried it didnt make any difference. It actually removes the vlan 51, so when did the "show ethernet-switching interface ge-0/0/10", vlan 51 disappears. The "native vlan" part in this link...
View ArticleRe: Cannot get native vlan to pass data traffic on ELS EX4300
Hello, With original configuration in place (disregarding change that I suggested), can you paste the output of following command? run show vlans 51 extensiveor run show vlans AREA51 extensive Regards,...
View ArticleRe: Virtual Chassis EX4550
The Virtual Chassis fast failover feature is a hardware-assisted failover mechanism that automatically reroutes traffic and reduces traffic loss in the event of a link or switch failure. If a link...
View ArticleRe: Cannot get native vlan to pass data traffic on ELS EX4300
HI Rushi, Sorry about the late reply. With origional config. Output seems ok to me but still no ping to the other end on native vlan. Tagged vlans ping ok.======================================set...
View ArticleQFX5100 Junos 15.1 xSTP and ELS-style trunk interfaces
Experimenting with Junos 15 on QFX.Is there a way to enable STP protocol on physical interface configured in ELS style?Its works on 14.1, but not on 15.1: # show interfaces xe-0/0/46...
View ArticleRe: Cannot get native vlan to pass data traffic on ELS EX4300
Hello, Following confirms that the Juniper Switch has correct configuration for both inbound & outbound frames. ge-0/0/10.0, untagged, trunk ------ Only one instance of ge-0/0/10 indicates we are...
View ArticleRe: Cannot get native vlan to pass data traffic on ELS EX4300
Try these commands !!! It will work set interfaces ge-x/x/x unit 0 family ethernet-switching port-mode trunkset interfaces ge-x/x/x unit 0 family ethernet-switching vlan members WLAN_Aset interfaces...
View ArticleRe: show interface description JWEB failed
is there any update regards the issue? thanks!
View ArticleTrigger Port Filter by RADIUS Policy
Hi, i got the following Problem: I setted up 802.1X on my EX2200 and it seems to work fine, but if someone fails the first Policy on my RADIUS I want to trigger an Port Filter on the Interface the...
View ArticleQFX5100-48S: Reboot reason(s): 0x2000: hypervisor reboot
Hi everyone, At present, there is a QFX5100 switch, automatic restart, Jul 7 10:29:28 2016 xxxxxxxxQFX5100-11 /kernel: %CONSOLE-6: kernel dumps on /dev/ad1s1b Jul 7 10:29:28 2016 xxxxxxxxQFX5100-11...
View ArticleEX4600 VC switch expansion
Hi, Currently I have a pair of EX4600 VC using 10G Fiber port as VC port. I'd like to add a new pair of EX4600 to the existing VC using 40G QSFP port as VC port. So we will have a mixture of 10G &...
View Article